ABSTRACT
The purpose of the project is to study the effect of liquid flow rate and gas flow rate on the pressure drop in a packed absorption tower and also to repair and restore the packed absorption tower to good working condition.

Trouble shooting revealed that the exit drain value was broken due to carelessness on the part of former user of the equipment.  We had to carry out glassblowing operations using borosilicate glass to construct another value.  Once this was done pressure build up within the tower was restored for absorption operation to take place.
A plot of log DO/H against log a superficial gas velocity gave 2.0774 2.3037 and 1.4940 respectively for slopes at varied superficial liquid velocity.

We concluded that increase in gas flow rate lead to increase in pressure drop since the graph obtained is linear.  There was a drop in slope from lower liquid rate to higher as operation neared flooding condition.  This means that industrially more cost is alluded to pumping operation to be successful. 
 
TABLE OF CONTENT
Title
Letter of transmittal
Approval page
Dedication
Acknowledgement
Abstract
Table of content

CHAPTER ONE
INTRODUCTION
1.2Objectives of the project

CHAPTER TWO
2.0Literature review
2.1Pressure drop
2.3Loading and flooding
2.4Description of tower
2.7packing characteristic 
2.7.3Water pump operation
2.8Design procedure of tower
2.8.2Selection of solvent

CHAPTER THREE
3.0Experiment procedure
3.1Glass  blowing process and procedure
3.1.1General physical properties of glass
3.1.2General chemical properties of glass
3.2Borosilicate glass properties
3.3Construction of drain value 

CHAPRER FOUR
Data analysis
Discussion

CHAPETR FIVE
Conclusion
Recommendation 
References
Appendix 1:summary of calculation
Graph  11:plot of log DP/H vs log a 46
Appendix 111:cost of repairing equipment 49
Appendix 111:scale drawing of packing absorption tower.
 

THE EFFECT OF LIQUID FLOERATE AND GAS FLOWRATE ON A PACKED ABSORPTION TOWER AND REPAIR OF EQUIPMENT
For more Info, call us on
+234 8130 686 500
or
+234 8093 423 853

Share This
  • Type: Project
  • Department: Chemical Engineering
  • Project ID: CNG0485
  • Access Fee: ₦5,000 ($14)
  • Pages: 58 Pages
  • Format: Microsoft Word
  • Views: 896
Payment Instruction
Bank payment for Nigerians, Make a payment of ₦ 5,000 to

Bank GTBANK
gtbank
Account Name Obiaks Business Venture
Account Number 0211074565

Bitcoin: Make a payment of 0.0005 to

Bitcoin(Btc)

btc wallet
Copy to clipboard Copy text

Details

Type Project
Department Chemical Engineering
Project ID CNG0485
Fee ₦5,000 ($14)
No of Pages 58 Pages
Format Microsoft Word

Related Works

ABSTRACT The effect of liquid flow rate, pipe size (diameter) and pipe orientation (inclination) on liquid hold-up was investigated. Liquid flow rate between 500 STB/day and 5000 STB/day was studied. An oil of 25˚API at an average temperature of 175˚F, a gas gravity of 0.65, water cut of 25% with water gravity of 1.07 and containing no free gas... Continue Reading
TABLE OF CONTENTS CHAPTER ONE 1.0 Introduction 1.1 Background of Study 1.2 Statement of Problem 1.3 Purpose of the Study 1.4 Scope of the Study 1.5 Research Question 1.6 Research Hypothesis 1.7 Significance of the Study 1.8... Continue Reading
TABLE OF CONTENTS CHAPTER ONE 1.0 Introduction 1.1 Background of Study 1.2 Statement of Problem 1.3 Purpose of the Study 1.4 Scope of the Study 1.5 Research Question 1.6 Research Hypothesis 1.7 Significance of the Study 1.8... Continue Reading
ABSTRACT Every Natural gas well ceases producing as reservoir pressure depletes. The usual liquid presence in the reservoir can cause further problems by accumulating in the wellbore and reducing production even more. There are a number of options in well completion to prevent liquid loading even before it becomes a problem. Tubing size and... Continue Reading
EVALUATION OF NIGERIAN GAS PRODUCTION & ELECTRICITY GENERATION FROM NATURAL GAS USING REGRESSION ANAYLSIS(1999-2014) CHAPTER ONE INTRODUCTION 1.1. Background of the study Nigeria is a nation that has been blessed with mineral resources ranging from solid minerals to crude oil deposits; right from the northern part of Nigeria to the southern... Continue Reading
ABSTRACT This is an abstract on the construction of a packed distillation column. A packed distillation column is used in the separating process distillation that is the separation of two miscible liquids. It was constructed by marking out the dimension of the column, condenser, pot, using steel rule scriber, oxyacetylene flame was used for... Continue Reading
ABSTRACT This is an abstract on the construction of a packed distillation column. A packed distillation column is used in the separating process distillation that is the separation of two miscible liquids. It was constructed by marking out the dimension of the column, condenser, pot, using steel rule scriber, oxyacetylene flame was used for... Continue Reading
ABSTRACT This is an abstract on the construction of a packed distillation column. A packed distillation column is used in the separating process distillation that is the separation of two miscible liquids.  It was constructed by marking out the dimension of the column, condenser, pot, using steel rule scriber, oxyacetylene flame was used for... Continue Reading
ABSTRACT This is an abstract on the construction of a packed distillation column. A packed distillation column is used in the separating process distillation that is the separation of two miscible liquids.  It was constructed by marking out the dimension of the column, condenser, pot, using steel rule scriber, oxyacetylene flame was used for... Continue Reading
Call Us
whatsappWhatsApp Us