CONSTRUCTION OF LOW POWER INDICATOR

  • Type: Project
  • Department: Science Lab Technology
  • Project ID: SLT0117
  • Access Fee: ₦5,000 ($14)
  • Chapters: 5 Chapters
  • Pages: 65 Pages
  • Methodology: nil
  • Reference: YES
  • Format: Microsoft Word
  • Views: 3.1K
  • Report This work

For more Info, call us on
+234 8130 686 500
or
+234 8093 423 853

ABSTRACT

A Low Power Indicator is a device that indicates by way of displaying light to indicate the level or strength of electrical power in a given circuit at a particular time. The transistors T1, T2, T3 are low power transistors that control the flow of electron in the circuit VR1 is employed to vary the frequency of the power.       

TABLE OF CONTENTS

Certification                                                                                                    ii
Dedication                                                                                                      iii
Acknowledgment                                                                                           iv 
Abstract                                                                                                          v 
Table of content                                                                                              vi
CHAPTER ONE
1.0       Introduction                                                                                        1
1.1       Types of low power indicator                                                             1
1.2       Practical examples                                                                               2 – 3

CHAPTER TWO 
2.0       Circuit diagram of L.E.D Zener P.S.U                                               4
2.1       Components of the circuit                                                                  4 – 5 
2.2       Circuit description                                                                              5 – 6

CHAPTER THREE 
3.0       Actual construction                                                                             7 
3.1       Advantages of using Vero-Board 
3.2       Soldering technique  
3.3       Soldering Iron
3.4       Precaution taken during construction

CHAPTER FOUR 
4.0       Circuit testing and fault finding

CHAPTER FIVE 
5.0       Conclusion 
Reference 

CHAPTER ONE

1.0       INTRODUCTION 
A Low Power Indicator can be defined as an indicator that is having a very low electrical supply or current situated in an electrical instrument which indicates the amount of power present in the instrument by their colour indication be it red, yellow or green.

1.1       TYPES OF A LOW POWER INDICATOR
A.        LIGHT – EMITTED DIODE (LED): - This is a junction diode made from the semiconductor gallium arsenide phosphide which has large band gap and hence a larger forward drop than silicon. Typical flooded panel – type LED indicators look good at 10MA forward current on a board inside an instrument one can usually get away with 2.5MA, particularly if one use a narrow-angle LED. When forward biased it emits red, yellow or green light depending on its exact composition. No conductor or light emission occurs for reverse bias which if it exceeds 5V, may damage the LED.

B.        LIQUID CRYSTAL DISPLAY (LCO): - This is a display that is usually is a driven by an a.c wave form otherwise their liquid guts (contents) are ruined. However, it driver chips have some way to generate a square – wave segment drive, synchronized to the LED backplane wave form. An example is the HC4543, the LED cousin of the HC4511 LED latch/decoded driver. LCD come in rather large panels that can display a line or two or text i.e they have ability to store several message and communicate via serial ports.

C.        LOW – BATTERY INDICATOR USES FLEA POWER: - This is a low indicator that consumes as little power as possible for a 9V, 450-MAhr alkaline battery, a 50 – PA low battery indication can by itself run the battery down in a little more than a year battery – powered devices that need to run continuously for a long time require battery indicators that consume minimal power. 

CONSTRUCTION OF LOW POWER INDICATOR
For more Info, call us on
+234 8130 686 500
or
+234 8093 423 853

Share This
  • Type: Project
  • Department: Science Lab Technology
  • Project ID: SLT0117
  • Access Fee: ₦5,000 ($14)
  • Chapters: 5 Chapters
  • Pages: 65 Pages
  • Methodology: nil
  • Reference: YES
  • Format: Microsoft Word
  • Views: 3.1K
Payment Instruction
Bank payment for Nigerians, Make a payment of ₦ 5,000 to

Bank GTBANK
gtbank
Account Name Obiaks Business Venture
Account Number 0211074565

Bitcoin: Make a payment of 0.0005 to

Bitcoin(Btc)

btc wallet
Copy to clipboard Copy text

Details

Type Project
Department Science Lab Technology
Project ID SLT0117
Fee ₦5,000 ($14)
Chapters 5 Chapters
No of Pages 65 Pages
Methodology nil
Reference YES
Format Microsoft Word

Related Works

ABSTRACT As new ideas unfold and technology become advanced with business increasingly being dependent on technology for their fundamental operation; the need for system availability is of paramount importance.           Uninterruptible power supply [INVERTER] maintain continuous supply of electric power to certain essential equipment... Continue Reading
DEDICATION We dedicate this project work to Almighty God, the source of all knowledge, wisdom and understanding, for being there for us throughout the period of our study and to our lovely parents, Mr. and Mrs. Abido, and Sir & Lady Christopher Korugbo for their parental care, who has always been our inspiration. ACKNOWLEDGEMENTS Thanks to God... Continue Reading
ABSTRACT This project work deals on the design and construction of an automatic power changeover that will change/transfer control from MAINS to Gen set and can switch ON/OFF the Gen automatically. The system integrates phase selector in MAINS and changeover to Gen. It is designed in several blocks all combined to from one functional unit. A +5v... Continue Reading
ABSTRACT This project work deals on the design and construction of an automatic power changeover that will change/transfer control from MAINS to Gen set and can switch ON/OFF the Gen automatically. The system integrates phase selector in MAINS and changeover to Gen. It is designed in several blocks all combined to from one functional unit. A +5v... Continue Reading
 ABSTRACT  The construction of a 3-phase motor operation indicator exposes the techniques and skills employed in the construction of complex electrical circuit. The combination of contactors overload relay and other component to achieved the desired goal is diagrammatically and descriptively treated of practical knowledge     TABLE OF CONTENTS... Continue Reading
 ABSTRACT  The construction of a 3-phase motor operation indicator exposes the techniques and skills employed in the construction of complex electrical circuit. The combination of contactors overload relay and other component to achieved the desired goal is diagrammatically and descriptively treated of practical knowledge     TABLE OF CONTENTS... Continue Reading
ABSTRACT Radiological workers appreciate the concept of radiological protection of patient in theory due to its benefits of avoiding radiation induced genetic and somatic effects. However, they tend to neglect the practical aspect of the topic thus, leading to large number of patient entering into the radiological diagnostic room without been... Continue Reading
This project is about water level indicator using raspberry pi. In this project we used led to  indicate the different levels and the raspberry pi to display were exactly the level is at in terms of  percentages. The simple water level indicator will activate an active buzzer which will make a  continuous noise when a certain level of water is... Continue Reading
ABSTRACT Radiological workers appreciate the concept of radiological protection of patient in theory due to its benefits of avoiding radiation induced genetic and somatic effects. However, they tend to neglect the practical aspect of the topic thus, leading to large number of patient entering into the radiological diagnostic room without been... Continue Reading
TABLE OF CONTENT   An Indicator Species & Identification   Description of Microcystis aeruginosa   Ecological Characteristics, Evolutionary Strategies & Ecological Class   What Makes Microcystis aeruginosa an Indicator of Disturbance   Successional Status   Agents that Promote Microcystis aeruginosa   Usefulness offs an Indicator References... Continue Reading
Call Us
whatsappWhatsApp Us