EVALUATION OF ROOM TEMPERATURE TRIBOCORROSION BEHAVIOUR OF AL-4.5CU/SIC PARTICULATE COMPOSITE IN NATURAL SEA WATER

  • Type: Project
  • Department: Material Science
  • Project ID: MCI0012
  • Access Fee: ₦5,000 ($14)
  • Pages: 14 Pages
  • Format: Microsoft Word
  • Views: 814
  • Report This work

For more Info, call us on
+234 8130 686 500
or
+234 8093 423 853

Room  temperature  tribocorrosion behaviour  of  Al-4.5%Cu/SiC particulate composite  was  evaluated against  stainless  steel  ball  in natural  sea  water.  Ab-initio,  the          Al-4.5%Cu  was  reinforced  with  5,10,15  and  20  %  SiC  reinforcements  to  produce  the Al-4.5%Cu/SiC  particulate  composite  by  stir  casting  method.  The  tribocorrosion  test  was carried  out  with  an  Anton  Paar  Tribometer  at  applied  loads  of  5  and  7  N.  The  surfaces  of  the control  and  worn  out  surfaces  were  characterized  by  scanning  electron  microscopy  (SEM);  the navigation  camera  of  the  SEM  machine  was  used  to  capture  the  exposed  areas  of the  composite that  were  subjected  to  tribocorrosion  prior  to  the  SEM.  From  the  results,  it  was  found  that  the control  sample  (Al-4.5%Cu)  was  more  susceptible  to  corrosion  and  wear  in  sea  water  than  the reinforced  (Al-4.5Cu%/SiC)  sample  under  the  loadings  considered  in  this  work.  The susceptibility  to  corrosion  and  wear  decreased  as  the  percent  composition  of  the  reinforcement was  increased;  the  synergistic  action  of  corrosion  and  wear  (tribocorrosion)  decreased  as  the reinforcement  was  increased.  The  pre  and  post-tribocorrosion  scanning  electron  microscopy (SEM)  images  of  the  test  samples  obtained  at  magnifications  of  2000x  and  2500x  revealed white  patches  of  SiC  particulates  embedded  in  dark  areas  of  Al-Cu  matrix  regions  and  appears to  be  fairly  distributed  throughout  the  matrix.  It  was  concluded  that  the  tribocorrosion  rate  of the  test  samples  decreased  with  increase  in  percentage  volume  fraction  of  the  SiC  particulate reinforcement.

Key  words:  Al-4.5%Cu/SiC;  seawater;  tribocorrosion;  room  temperature;  synergism;  SEM.

EVALUATION OF ROOM TEMPERATURE TRIBOCORROSION BEHAVIOUR OF AL-4.5CU/SIC PARTICULATE COMPOSITE IN NATURAL SEA WATER
For more Info, call us on
+234 8130 686 500
or
+234 8093 423 853

Share This
  • Type: Project
  • Department: Material Science
  • Project ID: MCI0012
  • Access Fee: ₦5,000 ($14)
  • Pages: 14 Pages
  • Format: Microsoft Word
  • Views: 814
Payment Instruction
Bank payment for Nigerians, Make a payment of ₦ 5,000 to

Bank GTBANK
gtbank
Account Name Obiaks Business Venture
Account Number 0211074565

Bitcoin: Make a payment of 0.0005 to

Bitcoin(Btc)

btc wallet
Copy to clipboard Copy text

Details

Type Project
Department Material Science
Project ID MCI0012
Fee ₦5,000 ($14)
No of Pages 14 Pages
Format Microsoft Word

Related Works

Room temperature tribocorrosion behaviour of Al-4.5%Cu/SiC particulate composite was evaluated against stainless steel ball in natural sea water. Ab-initio, the Al-4.5%Cu was reinforced with 5,10,15 and 20 % SiC reinforcements to produce the Al-4.5%Cu/SiC particulate composite by stir casting method. The tribocorrosion test was carried out with an... Continue Reading
Room  temperature  tribocorrosion behaviour  of  Al-4.5%Cu/SiC particulate composite  was  evaluated against  stainless  steel  ball  in natural  sea  water.  Ab-initio,  the          Al-4.5%Cu  was  reinforced  with  5,10,15  and  20  %  SiC  reinforcements  to  produce  the Al-4.5%Cu/SiC  particulate  composite... Continue Reading
ABSTRACT The purpose of the study was to design and implement a computerized temperature control system for a cold room. This work is also designed to monitor and detect any abnormality in the temperature value of any system thereby improving the efficiency and... Continue Reading
Design And Implementation Of A Computerized Temperature Control System For A Cold Room ABSTRACT The purpose of the study was to design and implement a computerized temperature control system for a cold room.       This work is also designed to monitor and detect any abnormality in the temperature value of any system thereby improving the... Continue Reading
ABSTRACT The purpose of the study was to design and implement a computerized temperature control system for a cold room. This work is also designed to monitor and detect any abnormality in the temperature value of any system thereby improving the efficiency and through put of that system. This piece will go a long way to monitor and control the... Continue Reading
ABSTRACT The purpose of the study was to design and implement a computerized temperature control system for a cold room. This work is also designed to monitor and detect any abnormality in the temperature value of any system thereby improving the efficiency and through put of that system. This piece will go a long way to monitor and control the... Continue Reading
TABLE OF CASES PAGES Archbold (Freightage) Ltd. v. S. Spnaglett Ltd (1981) 1 Q.B. 374 41 Asfar v. Blindell  (1896) 1 Q.B. 123 45 Boardance v. Phipps  (1967) 2 A.C. 46 58 Casebourn v. Avery and Houston  (1887) S.T.L.R. 795 41 Dakin v. Oxley  (1864) 15 C.B.N. 648 44... Continue Reading
ABSTRACT The purpose of the study was to establish whether Private Maritime Security Companies (PMSCs) in Nigeria was a solution to armed robbery at sea in Nigerian waters. The Private Maritime Security Companies in Nigeria operated under rules set by the Nigerian Navy being the main custodian of maritime security in Nigeria. Although attempts... Continue Reading
TABLE OF CONTENTS TABLE OF CONTENTS ................................................................................................. i ABBREVIATIONS ......................................................................................................... iii DECLARATION... Continue Reading
Call Us
whatsappWhatsApp Us