ABSTRACT
In the mechanical engineering department of institute of management and technology there are many machines but it is not all that is functioning well.
This may airless as a   result of lack of maintenance which is a prove in the breakdown of the air conditioner.
The quality and effectiveness of materials were mated very well as referred to machine maintenance.
The cost of maintenance was minimized jet reaching a highly victorious rehabilitation.
In the course of rehabilitation and repair of a faulty air conditioner, suitable tools such as manifold gauge, refrigerant cost and quality of equipment were put into consideration.      

 
TABLE OF CONTENTS 

Title page
Letter of transmittal 
Approval page
Dedication
Acknowledgement 
Abstracts
Table of contents

CHAPTER ONE 
1.0 Introduction
1.1 Literature Review

CHAPTER TWO 
2.0 The Air Conditioning Cycle Analysis 
2.1 Air Conditioning Maintenance 
2.2 Repairs and Preparation 
2.3 Detection of Faults and Repairs
2.4 Perceptional Measure
2.5 Air Conditioner Operation Principles 
2.6 Application of Air Conditioner 
2.7 The Component Parts in Air Conditioner
2.8 Sequence of Operation 
2.9 The Cost Analysis 

CHAPTER THREE
Conclusion
3.1 Recommendation
3.2 References 
  

         

REPAIR AND REHABILITATION OF A FAULTY AIR CONDITIONER IN THE MECHANICAL ENGINEERING DEPARTMENT AT THE INSTITUTE OF MANAGEMENT AND TECHNOLOGY (I.M.T.), ENUGU

Share This

Details

Type Project
Department Mechanical Engineering
Project ID MCE0189
Price ₦3,000 ($9)
No of Pages 35 Pages
Format Microsoft Word

500
Leave a comment...

    Details

    Type Project
    Department Mechanical Engineering
    Project ID MCE0189
    Price ₦3,000 ($9)
    No of Pages 35 Pages
    Format Microsoft Word

    Related Works

    ABSTRACT In the mechanical engineering department of institute of management and technology there are many machines but it is not all that is functioning well. This may airless as a result of lack of maintenance which is a prove in the breakdown of the air conditioner. The quality and effectiveness of materials were mated very well as referred to... Continue Reading
    ABSTRACT In the mechanical engineering department of institute of management and technology there are many machines but it is not all that is functioning well. This may airless as a   result of lack of maintenance which is a prove in the breakdown of the air conditioner. The quality and effectiveness of materials were mated very well as referred... Continue Reading
    ABSTRACT This report covers all activities candied out to rehabilitate a faulty refrigerator. First and foremost, we diagnosed the faulty refrigerator using the basic instruments to know the faults. After which we bought the necessary standard items that caused the fault.  We then started work on it by replacing necessary instruments.  We... Continue Reading
    ABSTRACT In all types of air –conditioning work a through knowledge of basic principal is varying important. The report of the project “re pair and rehabilitation of a faulty Air–conditioner” serves as guide to project implementation. It explains and illustrates the import principle of operation and various maintenance procedures in an... Continue Reading
    ABSTRACT Mechanical Engineering Department of the named Institute has many non – operational malhiues. Sequel to the fact, maintenance was poorly excuted which resulted to the breakdown deep freezer. Quality and effectiveness of machine maintenance were well observed. Also, a minimized maintenance and a highly successful repair was adopted. In... Continue Reading
    ABSTRACT Mechanical Engineering Department of the Institute of Management and Technology has many non – functional machines. This is caused as a result of poor maintenance culture, which in turn resulted to breakdown of the Deep Freezer under review.... Continue Reading
    ABSTRACT The need for an authentic and reliable report relating to the repairs and rehabilitation of a faulty air-conditioner is inevitable. Many homes and offices uses the air-conditioner to cool he temperature in their respective homes. So the maintenance of the air-conditioner should be a top priority of every individual in order to avoid huge... Continue Reading
    ABSTRACT The need for an authentic and reliable report relating to the repairs and rehabilitation of a faulty air conditioner is inevitable.  The fact that many people use the air conditioner to cool the temperature in their respective home and offices make its maintenance a top priority to every individual in order to avoid huge expenditure in... Continue Reading
    PREFACE A new machine/equipment will provide satisfactory service if kept in proper operating condition. The inevitability of less than 100% reliability of any machine/equipment after some period and maintenance. Also in system of any complexity, certain replacement adjustments are... Continue Reading
    REPAIR OF DEEP FREEZER ABSTRACT This work gives an account of all activities carried out to restore a faulty and abandoned deep freezer to normal functioning. This report therefore contains the different stages embarked in the execution of the project. These include the literature back ground, checking’s conducted, cleaning, repair operations... Continue Reading