The cathode ray Oscilloscope plays a very important role in the laboratories, for instance it is used to measure frequency and voltage of a signal it is equally used for study current fluctuation in electric power supply the cathode ray oscilloscope is made up of three major part, they are the cathode ray tube, which is the major integral part A the Oscilloscope also the other important[1 parts of the Oscilloscope is the power supply unit and the vertical as well as horizontal amplifier. Some of the cathode ray oscillioscope are calibrated manually while some are already calibrated by the manufacturers. The subpart of the oscilloscope which include Cathode Ray Tube (CRT) is made of three (3) major parts namely the electron gun which produces electron before acceleration and the second sub part of the instrument in the deflecting plates which helps to deflect the electron towards the screen where it is seen. This cathode Ray Oscilloscope works in the principle that the signal to be displayed is amplified by the vertical amplifier and applied to the vertical deflection plates of the CRT, a portion of the signal in the vertical amplifier is applied to the sweep trigger as a triggering signal. Then the sweep trigger generates a pulse coincident with a selected point in the cycle of the triggering signal. This pulse turns on the sweep generator. Initiating the saw-tooth wave form.
TITLE PAGE
Title Page i
Certification ii
Dedication iii
Acknowledge iv
Abstract.v
Table of Contents vi
CHAPTER ONE
1.0Introduction 1
1.1The Background Review of the Cathode Ray Oscilloscope 1
1.2Limitations of the Study 7
1.3Objective of the study 8
1.4Definition of Terms 8
CHAPTER TWO
2.1Mode of operation of Cathode Ray Oscilloscope 9
2.2Scheme Diagram of CRO10
2.3 The Parts of Cathode Ray Oscilloscope (CRO) 10
2.4Schematic Diagram of Cathode Ray Tube 11
2.4.1The pars of Cathode Ray (CRT)12
2.4.2Vertical Amplifier 13
2.4.3Delay Line14
2.4.4The Power Supply Section 15
2.4.5Time Base Generator 15
2.4.6Horizontal Sweep Section 15
CHAPTER THREE
3.0Calibration and setting up of cathode Ray
Oscillioscope 17
3.1Setting of Cathode Ray Oscilloscope 17
3.2The Summary for setting up CRO23
3.3Calibration of Cathode Ray Oscilloscope 24
CHAPTER FOUR
4.0Application of Cathode Ray Oscilloscope in
Laboratory 25
4.1CRO as a voltmeter25
4.2Frequency Measurement with CRO29
4.3Measurement of Voltage and Time Period 30
CHAPTER FIVE
5.0Summary, Conclusion and Recommendation32
5.1Summary 32
5.2Conclusion 33
5.3Recommendation 34
REFERENCES 35
CALIBRATION AND APPLICATION OF CATHODE RAY OSCILLOSCOPE IN OUR LABORATORY
ABSTRACT The Nigerian economy is filled with different kinds of services providing industries, ramping from the large ones like banks to very small ones such as hair saloon services. The deepering economic problems in the country has made services provision of all kinds very expensive and competitive. The only solution to survive is to engage... Continue Reading
Electromagnetic Distance Measurement (EDM) equipment is calibrated on a base to determine instrument constants and errors. A series of measurements on a base can also be used to check the performance and reliability of the instrument over time and to assess its precision against the manufacturer's specifications. This research work, the... Continue Reading
ABSTRACT A Linear Variable Differential Transformer (LVDT) was constructed having a primary winding of 245 turns and two secondary windings of 100 turns each. The device was calibrated with a graduated cylindrical rod. The graduated rod when inserted between the hollow tube which has the windings gave output voltages of ±0.046V, ±0.51V,... Continue Reading
Crude oil viscosity is an important parameter which is considered in both porous media and in pipeline channels. Estimating oil viscosity at various operating conditions of pressure and temperature is of great value to petroleum engineers. In petroleum and reservoir engineering, we are often faced with the analysis of processes which involve... Continue Reading
ABSTRACT This research work presents the results of the thermal power calibration of Nigeria Research Reactor-1 (NIRR-1), a low power Miniature Neutron Source Reactor (MNSR), using calorimetric and heat balance methods. The calibration was performed at... Continue Reading
ABSTRACT This research work presents the results of the thermal power calibration of Nigeria Research Reactor-1 (NIRR-1), a low power Miniature Neutron Source Reactor (MNSR), using calorimetric and heat balance methods. The calibration was performed at two different power levels: half power (15kW) and full power (30kW). The calorimetric method... Continue Reading
This project report describes a mobile android based job finder and applier. There is a crisis in Nigeria right now on job opportunities and availability. There is a huge population with fewer jobs every year in the country. Getting a job is a struggle and it is affecting mostly the less privileged. The internet is now a common place for engaging... Continue Reading
ABSTRACT This work presents the raw materials and steps used in the refurbishment of microbiology laboratory at institute of management and technology. These material used include marble tiles, white cement, white glue, filling machine, cutting machine, board and nose mask the steps includes filling of the... Continue Reading
ABSTRACT This work presents the raw materials and steps used in the refurbishment of microbiology laboratory at institute of management and technology. These material used include marble tiles, white cement, white glue, filling machine, cutting machine, board and nose mask the steps includes filling of the... Continue Reading
CHAPTER ONE 1.0 INTRODUCTION Gases, dust particles, water vapour and air contain microorganisms. There are vegetable cells and spores of bacteria, fungi and algae, viruses and protozoa cysts. Since air is often exposed to sunlight, it has a... Continue Reading